<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-11 14-15-34
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 61 dBuV SANDELS
Pilot RDS Phase Difference
4.6 kHz 5.4 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 75 kHz 15346 23,9476
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,1 dBr 5,60 dBr 6,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 75 kHz MIN: 11 kHz % above 76 kHz: 23,9476 Acquired: 2025/03/11 14.14.30 Total samples: 15346 Equivalent time: 0:12:47 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 6,3 dBr MIN: 3,1 dBr AVE: 5,60 dBr % above 12,2 dBr: 0,0 Last value: 6,1 dBr (2025/03/11 14.14.30) 14.00 14.02 14.04 14.06 14.08 14.10 14.12 14.14 0 2 4 6 Pm [dBr]